Universal Hotels – Maintenance

Universal – Monthly, Civic – Monthly, Oxford – Monthly

Selected Value: 0

Testing of equipment

Main speaker system
Turn down all amplifier channels. Run music on the sound system at a reasonable level. Turn up each amp channel one at a time and listen to the connected speaker(s) to verify they sound okay. Note – Universal Superclub speakers must be muted / unmuted via Symvue, not on amps. Return all amps to original volume levels when complete.

Maintenance tasks

Amplifier rack
All amplifier air vents and fan grilles are to be cleaned. Dust is to be dislodged using a soft brush, and then removed with a vacuum. Do not allow the vacuum to spin the cooling fans up as this causes the bearings to fail prematurely. For amplifiers with removable air filters (X8, T604, Quattrocannali), unscrew the front panel as required, remove the air filter, wash it in warm soapy water, rinse, dry, and reinstall. Rack to be vacuumed out of any dust.
Audio processors and network switch(es)
System DSP and network switch air vents and fan grilles are to be cleaned. Dust is to be dislodged using a soft brush, and then removed with a vacuum. Do not allow the vacuum to spin the cooling fans up as this causes the bearings to fail prematurely.
Audio and Lighting consoles and computers
Gentle brush console surfaces to remove dust between fader tracks and buttons. Brush keyboards down. Use dampened cloth to clean console and computer casings.
Lighting fixture vents and fans
Remove excess dust using soft brush to dislodge confetti and dust and air compressor at a distance to blow residue away. Do not allow the compressor to spin the cooling fans up as this causes the bearings to fail prematurely. Blow compressed air into and around the yoke of the fixtures to remove any confetti which may be caught in the mechanisms.
Operational area tidying
Remove and dispose any rubbish or items not belonging in ops booth. Wipe down hard surfaces with cleaning spray and cloth.
Were any additional tasks carried out?